On the ICC ICMPP04860 copper rack patch panel, the fixed Ethernet cable terminates at the rear 110 IDC block. In a LAN, a separate patch cord connects the patch panel to the switch. ICC panel specifications · Fluke Networks cabling guide
Check the rack fit and identify the wiring legends
- ICC lists the ICMPP04860 for standard 19-inch racks. ICC panel specifications
- Use the panel’s color-coded TIA-568A or TIA-568B diagram as a wiring reference. Fluke Networks identifies mixed 568A and 568B cabling as a likely cause in its crossed-pair example. ICC panel specifications · Fluke Networks crossed-pair example
Check the run with a MicroScanner2
For a fixed run from a patch panel to a wall outlet, test between the panel jack and that outlet. Fluke Networks permanent-link guide · MicroScanner2 test procedure
- Turn on the MicroScanner2. If it is in coaxial test mode, press PORT to switch to twisted-pair test mode. MicroScanner2 test procedure
- Connect the tester at one end of the run and the wiremap adapter at the other. Leave the far-end adapter connected for a complete wiremap. MicroScanner2 test procedure
- Check the wiremap for opens, shorts, crossed wires, crossed pairs and split pairs. In Fluke’s crossed-pair example, the pair on pins 1 and 2 and the pair on pins 3 and 6 both flash. MicroScanner2 results and fault examples
Patch the panel jack to the switch
In a LAN, connect a patch cord from the patch panel to the switch. Fluke Networks cabling guide
Evidence and limits. This guide follows ICC’s ICMPP04860 product documentation and Fluke Networks’ MicroScanner2 procedure dated February 26, 2014. Documentation was checked on 2026-11-26. No hands-on testing was performed for this article. Fluke Networks covers permanent-link and channel testing in its separate cabling guide. ICC panel specifications · MicroScanner2 test procedure · Fluke Networks cabling guide